When initializing the PHY control register, the FIFO depth bits are written without reading the previous register value, i.e. all other bits are overwritten with zero. This disables automatic MDI-X configuration, which is enabled by default. Fix initialization by doing a read/modify/write operation. Signed-off-by: Stefan Hauser <stefan@shauser.net> Reviewed-by: Florian Fainelli <f.fainelli@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>