[ Upstream commit 3a6f994f848a69deb2bf3cd9d130dd0c09730e55 ] The addition of 3WIRE support would affect MOSI direction even when still in standard (4 wire) mode. This can lead to MOSI being at an invalid logic level when a device driver sets an SPI message with a NULL tx_buf. spi.h states that if tx_buf is NULL then "zeros will be shifted out ... " If MOSI is tristated then the data shifted out is subject to pull resistors, keepers, or in the absence of those, noise. This issue came to light when using spi-gpio connected to an ADS7843 touchscreen controller. MOSI pulled high when clocking MISO data in caused the SPI device to interpret this as a command which would put the device in an unexpected and non-functional state. Fixes:4b859db2c6
("spi: spi-gpio: add SPI_3WIRE support") Fixes:5132b3d283
("spi: gpio: Support 3WIRE high-impedance turn-around") Signed-off-by: Kris Bahnsen <kris@embeddedTS.com> Link: https://lore.kernel.org/r/20221207230853.6174-1-kris@embeddedTS.com Signed-off-by: Mark Brown <broonie@kernel.org> Signed-off-by: Sasha Levin <sashal@kernel.org>