瀏覽代碼

qcacld-3.0: Avoid changing measurement duration units in beacon report

Currently, while processing the beacon report req and response the
measurement duration units changed from MS to TU and TU to MS
respectively.
Avoid this conversion as both are close units.

Change-Id: I663b7c8969904a373461fb80c7d505c96e74b48f
CRs-Fixed: 2431912
Bala Venkatesh 6 年之前
父節點
當前提交
40f20fd88e
共有 1 個文件被更改,包括 2 次插入2 次删除
  1. 2 2
      core/mac/src/pe/rrm/rrm_api.c

+ 2 - 2
core/mac/src/pe/rrm/rrm_api.c

@@ -591,7 +591,7 @@ rrm_process_beacon_report_req(struct mac_context *mac,
 		pBeaconReq->measurement_request.Beacon.regClass;
 	pSmeBcnReportReq->channelInfo.channelNum =
 		pBeaconReq->measurement_request.Beacon.channel;
-	pSmeBcnReportReq->measurementDuration[0] = SYS_TU_TO_MS(measDuration);
+	pSmeBcnReportReq->measurementDuration[0] = measDuration;
 	pSmeBcnReportReq->fMeasurementtype[0] =
 		pBeaconReq->measurement_request.Beacon.meas_mode;
 	qdf_mem_copy(pSmeBcnReportReq->macaddrBssid,
@@ -859,7 +859,7 @@ rrm_process_beacon_report_xmit(struct mac_context *mac_ctx,
 					bss_desc->startTSF,
 					sizeof(bss_desc->startTSF));
 				beacon_report->measDuration =
-					SYS_MS_TO_TU(beacon_xmit_ind->duration);
+					beacon_xmit_ind->duration;
 				beacon_report->phyType = bss_desc->nwType;
 				beacon_report->bcnProbeRsp = 1;
 				beacon_report->rsni = bss_desc->sinr;