qcacld-3.0: Avoid changing measurement duration units in beacon report

Currently, while processing the beacon report req and response the
measurement duration units changed from MS to TU and TU to MS
respectively.
Avoid this conversion as both are close units.

Change-Id: I663b7c8969904a373461fb80c7d505c96e74b48f
CRs-Fixed: 2431912
Bala Venkatesh 6 yıl önce
ebeveyn
işleme
40f20fd88e
1 değiştirilmiş dosya ile 2 ekleme ve 2 silme
  1. 2 2
      core/mac/src/pe/rrm/rrm_api.c

+ 2 - 2
core/mac/src/pe/rrm/rrm_api.c

@@ -591,7 +591,7 @@ rrm_process_beacon_report_req(struct mac_context *mac,
 		pBeaconReq->measurement_request.Beacon.regClass;
 	pSmeBcnReportReq->channelInfo.channelNum =
 		pBeaconReq->measurement_request.Beacon.channel;
-	pSmeBcnReportReq->measurementDuration[0] = SYS_TU_TO_MS(measDuration);
+	pSmeBcnReportReq->measurementDuration[0] = measDuration;
 	pSmeBcnReportReq->fMeasurementtype[0] =
 		pBeaconReq->measurement_request.Beacon.meas_mode;
 	qdf_mem_copy(pSmeBcnReportReq->macaddrBssid,
@@ -859,7 +859,7 @@ rrm_process_beacon_report_xmit(struct mac_context *mac_ctx,
 					bss_desc->startTSF,
 					sizeof(bss_desc->startTSF));
 				beacon_report->measDuration =
-					SYS_MS_TO_TU(beacon_xmit_ind->duration);
+					beacon_xmit_ind->duration;
 				beacon_report->phyType = bss_desc->nwType;
 				beacon_report->bcnProbeRsp = 1;
 				beacon_report->rsni = bss_desc->sinr;