[ Upstream commit 6469b2feade8fd82d224dd3734e146536f3e9f0e ] Fix "thermal_sys: cpu_thermal: Failed to read thermal-sensors cells: -2" error on boot for omap3/4. This is caused by wrong addressing in the dts for bandgap sensor for single sensor instances. Note that omap4-cpu-thermal.dtsi is shared across omap4/5 and dra7, so we can't just change the addressing in omap4-cpu-thermal.dtsi. Cc: Ivaylo Dimitrov <ivo.g.dimitrov.75@gmail.com> Cc: Carl Philipp Klemm <philipp@uvos.xyz> Cc: Merlijn Wajer <merlijn@wizzup.org> Cc: Pavel Machek <pavel@ucw.cz> Reviewed-by: Sebastian Reichel <sebastian.reichel@collabora.com> Fixes:a761d517bb
("ARM: dts: omap3: Add cpu_thermal zone") Fixes:0bbf6c54d1
("arm: dts: add omap4 CPU thermal data") Signed-off-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
41 lines
998 B
Plaintext
41 lines
998 B
Plaintext
/*
|
|
* Device Tree Source for OMAP3 SoC CPU thermal
|
|
*
|
|
* Copyright (C) 2017 Texas Instruments Incorporated - https://www.ti.com/
|
|
*
|
|
* This file is licensed under the terms of the GNU General Public License
|
|
* version 2. This program is licensed "as is" without any warranty of any
|
|
* kind, whether express or implied.
|
|
*/
|
|
|
|
#include <dt-bindings/thermal/thermal.h>
|
|
|
|
cpu_thermal: cpu_thermal {
|
|
polling-delay-passive = <250>; /* milliseconds */
|
|
polling-delay = <1000>; /* milliseconds */
|
|
coefficients = <0 20000>;
|
|
|
|
thermal-sensors = <&bandgap>;
|
|
|
|
cpu_trips: trips {
|
|
cpu_alert0: cpu_alert {
|
|
temperature = <80000>; /* millicelsius */
|
|
hysteresis = <2000>; /* millicelsius */
|
|
type = "passive";
|
|
};
|
|
cpu_crit: cpu_crit {
|
|
temperature = <90000>; /* millicelsius */
|
|
hysteresis = <2000>; /* millicelsius */
|
|
type = "critical";
|
|
};
|
|
};
|
|
|
|
cpu_cooling_maps: cooling-maps {
|
|
map0 {
|
|
trip = <&cpu_alert0>;
|
|
cooling-device =
|
|
<&cpu THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
|
};
|
|
};
|
|
};
|