Files
android_kernel_xiaomi_sm8450/drivers/pwm
Uwe Kleine-König 8b98e7a45e pwm: sifive: Reduce time the controller lock is held
[ Upstream commit 0f02f491b786143f08eb19840f1cf4f12aec6dee ]

The lock is only to serialize access and update to user_count and
approx_period between different PWMs served by the same pwm_chip.
So the lock needs only to be taken during the check if the (chip global)
period can and/or needs to be changed.

Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Tested-by: Emil Renner Berthing <emil.renner.berthing@canonical.com>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Stable-dep-of: 334c7b13d383 ("pwm: sifive: Always let the first pwm_apply_state succeed")
Signed-off-by: Sasha Levin <sashal@kernel.org>
2023-03-11 16:40:08 +01:00
..
2023-01-14 10:16:24 +01:00