Ido Schimmel 9ac9f07f0f selftests: mirror_gre_bridge_1q: Avoid changing PVID while interface is operational
commit 3122257c02afd9f199a8fc84ae981e1fc4958532 upstream.

In emulated environments, the bridge ports enslaved to br1 get a carrier
before changing br1's PVID. This means that by the time the PVID is
changed, br1 is already operational and configured with an IPv6
link-local address.

When the test is run with netdevs registered by mlxsw, changing the PVID
is vetoed, as changing the VID associated with an existing L3 interface
is forbidden. This restriction is similar to the 8021q driver's
restriction of changing the VID of an existing interface.

Fix this by taking br1 down and bringing it back up when it is fully
configured.

With this fix, the test reliably passes on top of both the SW and HW
data paths (emulated or not).

Fixes: 239e754af8 ("selftests: forwarding: Test mirror-to-gretap w/ UL 802.1q")
Signed-off-by: Ido Schimmel <idosch@nvidia.com>
Reviewed-by: Petr Machata <petrm@nvidia.com>
Link: https://lore.kernel.org/r/20220502084507.364774-1-idosch@nvidia.com
Signed-off-by: Paolo Abeni <pabeni@redhat.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2022-05-12 12:25:41 +02:00
..

Motivation
==========

One of the nice things about network namespaces is that they allow one
to easily create and test complex environments.

Unfortunately, these namespaces can not be used with actual switching
ASICs, as their ports can not be migrated to other network namespaces
(NETIF_F_NETNS_LOCAL) and most of them probably do not support the
L1-separation provided by namespaces.

However, a similar kind of flexibility can be achieved by using VRFs and
by looping the switch ports together. For example:

                             br0
                              +
               vrf-h1         |           vrf-h2
                 +        +---+----+        +
                 |        |        |        |
    192.0.2.1/24 +        +        +        + 192.0.2.2/24
               swp1     swp2     swp3     swp4
                 +        +        +        +
                 |        |        |        |
                 +--------+        +--------+

The VRFs act as lightweight namespaces representing hosts connected to
the switch.

This approach for testing switch ASICs has several advantages over the
traditional method that requires multiple physical machines, to name a
few:

1. Only the device under test (DUT) is being tested without noise from
other system.

2. Ability to easily provision complex topologies. Testing bridging
between 4-ports LAGs or 8-way ECMP requires many physical links that are
not always available. With the VRF-based approach one merely needs to
loopback more ports.

These tests are written with switch ASICs in mind, but they can be run
on any Linux box using veth pairs to emulate physical loopbacks.

Guidelines for Writing Tests
============================

o Where possible, reuse an existing topology for different tests instead
  of recreating the same topology.
o Tests that use anything but the most trivial topologies should include
  an ASCII art showing the topology.
o Where possible, IPv6 and IPv4 addresses shall conform to RFC 3849 and
  RFC 5737, respectively.
o Where possible, tests shall be written so that they can be reused by
  multiple topologies and added to lib.sh.
o Checks shall be added to lib.sh for any external dependencies.
o Code shall be checked using ShellCheck [1] prior to submission.

1. https://www.shellcheck.net/