Add logic in enable_thermal_genl_check to avoid
thermal-hal being woken up all the time by on-die sensor.
When the temperature of the on-die sensor thermal_zone updates,
the thermal_zone_device_update() will be called to handle thermal
and then the netlink events will be sent
through thermal_notify_tz_trip_().
But there is currently no way to filter thermal_zone
in the thermal_netlink, so many netlink events will be sent
in a short amount of time. Because the on-die sensors
are very sensitive. Their temperature may jump up and down
quickly in a few ms.
Bug: 170682696
Test: boot and thermal-hal can receive thermal genl events from kernel
Change-Id: Idb3f4b07a2a2740c01d8785910878bfe6edc832d
Signed-off-by: davidchao <davidchao@google.com>
Add vendor enable_thermal_genl_check logic.
To avoid thermal-hal being woken up all the time by thermal genl events,
only the selected thermal_zone and cooling_device can send events from
kernel.
Bug: 170682696
Test: boot and thermal-hal can receive thermal genl events from kernel
Change-Id: I8f49d67963bed9d6d1f11c74bd274dc8967407c1
Signed-off-by: davidchao <davidchao@google.com>
(cherry picked from commit 88133a5b0b63a55dfb138e2150a6fd22b81c65a2)
Signed-off-by: J. Avila <elavila@google.com>