Since commit d68778b80d ("rtc: initialize output parameter for read
alarm to "uninitialized"") there is no need to explicitly set
unsupported members to -1. So drop the respective assignments from
drivers.
Signed-off-by: Uwe Kleine-König <uwe@kleine-koenig.org>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Year field must be in BCD format, according to
hym8563 datasheet.
Due to the bug year 2016 became 2010.
Fixes: dcaf038493 ("rtc: add hym8563 rtc-driver")
Signed-off-by: Alexander Kochetkov <al.kochet@gmail.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Sometimes the irq line is not connected to any soc-pin. This does
not hinder basic timekeeping functionality of the rtc, so probe
should not fail in this case.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
The hym8563 datasheet describes the clock output control-bit as "when set
to logic 0, the square wave output is enable, when set to logic 1, the
CLKOUT output is inhibited". But in reality the setting is exactly
opposite.
Before now, the clock output was not really used, but on the rk3288 soc
this generated clock is used to supply the temperature sensor block and
the swapped bit value prevented it from working. With the corrected
value, the tsadc now reports correct values.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
When the clock is disabled, do not return a rate of 0 but instead return
the rate the clock will be running at after it gets enabled. This
prevents problems when the core clock code is trying to determine a
suitable rate, while the clock is still off.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The alarm of the hym8563 only supports a minute accuracy, while the uie
wants an alarm one second in the future. Therefore things like the
select() syscall will fail with a timeout, because the next alarm will
happen in a worst case of 60 seconds.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Cc: <stable@vger.kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>