[ Upstream commit 1205b688c92558a04d8dd4cbc2b213e0fceba5db ]
Dan reported following static checker warnings
tools/testing/selftests/resctrl/resctrl_val.c:545 measure_vals()
warn: 'bw_imc' unsigned <= 0
tools/testing/selftests/resctrl/resctrl_val.c:549 measure_vals()
warn: 'bw_resc_end' unsigned <= 0
These warnings are reported because
1. measure_vals() declares 'bw_imc' and 'bw_resc_end' as unsigned long
variables
2. Return value of get_mem_bw_imc() and get_mem_bw_resctrl() are assigned
to 'bw_imc' and 'bw_resc_end' respectively
3. The returned values are checked for <= 0 to see if the calls failed
Checking for < 0 for an unsigned value doesn't make any sense.
Fix this issue by changing the implementation of get_mem_bw_imc() and
get_mem_bw_resctrl() such that they now accept reference to a variable
and set the variable appropriately upon success and return 0, else return
< 0 on error.
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Tested-by: Babu Moger <babu.moger@amd.com>
Signed-off-by: Fenghua Yu <fenghua.yu@intel.com>
Signed-off-by: Shuah Khan <skhan@linuxfoundation.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
[ Upstream commit d81343b5eedf84be71a4313e8fd073d0c510afcf ]
iMC (Integrated Memory Controller) counters are usually at
"/sys/bus/event_source/devices/" and are named as "uncore_imc_<n>".
num_of_imcs() function tries to count number of such iMC counters so that
it could appropriately initialize required number of perf_attr structures
that could be used to read these iMC counters.
num_of_imcs() function assumes that all the directories under this path
that start with "uncore_imc" are iMC counters. But, on some systems there
could be directories named as "uncore_imc_free_running" which aren't iMC
counters. Trying to read from such directories will result in "not found
file" errors and MBM/MBA tests will fail.
Hence, fix the logic in num_of_imcs() such that it looks at the first
character after "uncore_imc_" to check if it's a numerical digit or not. If
it's a digit then the directory represents an iMC counter, else, skip the
directory.
Reported-by: Reinette Chatre <reinette.chatre@intel.com>
Tested-by: Babu Moger <babu.moger@amd.com>
Signed-off-by: Fenghua Yu <fenghua.yu@intel.com>
Signed-off-by: Shuah Khan <skhan@linuxfoundation.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
MBM (Memory Bandwidth Monitoring) test is the first implemented selftest.
It starts a stressful memory bandwidth benchmark and assigns the
bandwidth pid in a resctrl monitoring group. Read and compare perf IMC
counter and MBM total bytes for the benchmark. The numbers should be
close enough to pass the test.
Default benchmark is built-in fill_buf. But users can specify their
own benchmark by option "-b".
We can add memory bandwidth monitoring for multiple processes in the
future.
Co-developed-by: Sai Praneeth Prakhya <sai.praneeth.prakhya@intel.com>
Signed-off-by: Sai Praneeth Prakhya <sai.praneeth.prakhya@intel.com>
Co-developed-by: Babu Moger <babu.moger@amd.com>
Signed-off-by: Babu Moger <babu.moger@amd.com>
Signed-off-by: Fenghua Yu <fenghua.yu@intel.com>
Signed-off-by: Shuah Khan <skhan@linuxfoundation.org>