There is a forever loop calling iio_channel_release() because the
"chan < " part of the "chan < ARRAY_SIZE()" is missing. This is in both
the error handling on probe and also in the remove function.
The other thing is that it's possible for some of the elements of the
adc_bat->channel[chan] array to be an ERR_PTR(). I've changed them to be
NULL instead. We're still not allowed to pass NULLs to
iio_channel_release() so I've added a check.
Finally, I removed an unused "chan = ARRAY_SIZE(gab_chan_name);" statement
as a small cleanup.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Fix this link error on s390:
ERROR: "devm_request_threaded_irq" [drivers/power/goldfish_battery.ko] undefined!
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
randconfig complains about:
drivers/power/da9030_battery.c:113: error: field ‘nb’ has incomplete type
because there is no direct include for notifier.h which defines
struct notifier_block.
Signed-off-by: Michal Hocko <mhocko@suse.cz>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
All in-kernel users of class_find_device() don't really need mutable
data for match callback.
In two places (kernel/power/suspend_test.c, drivers/scsi/osd/osd_uld.c)
this patch changes match callbacks to use const search data.
The const is propagated to rtc_class_open() and power_supply_get_by_name()
parameters.
Note that there's a dev reference leak in suspend_test.c that's not
touched in this patch.
Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Acked-by: Grant Likely <grant.likely@secretlab.ca>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
For iio_channel_get to work with OF based configurations, it needs the
consumer device pointer instead of the consumer device name as argument.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Anton Vorontsov <anton@enomsg.org>
Acked-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Reported temperature can be also negative, so cache value in non negative
Kelvin degree.
Signed-off-by: Pali Rohár <pali.rohar@gmail.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
"pdata" and "pchg->pdata" are the same. Changing the function call to
pdata->get_batt_present() makes it match the check and it's a little
cleaner.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Milo Kim <milo.kim@ti.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Pull a huge ab8500/pm2301 pile of changes from Lee Jones. Lee did an
awesome job cleaning this stuff up and thus brought ab8500 Stericsson's
development tree much closer to the mainline. Even more changes to come,
though.
Conflicts:
drivers/power/Kconfig
Power supply subsystem creates thermal zone device for the property
'POWER_SUPPLY_PROP_TEMP' which requires thermal subsystem to be ready
before 'ab8500 battery temperature monitor' driver is initialized. ab8500
btemp driver is initialized with subsys_initcall whereas thermal subsystem
is initialized with fs_initcall which causes
thermal_zone_device_register(...) to crash since the required structure
'thermal_class' is not initialized yet:
Unable to handle kernel NULL pointer dereference at virtual address 000000a4
pgd = c0004000
[000000a4] *pgd=00000000
Internal error: Oops: 5 [#1] PREEMPT SMP ARM
Modules linked in:
CPU: 0 Tainted: G W (3.8.0-rc4-00001-g632fda8-dirty #1)
PC is at _raw_spin_lock+0x18/0x54
LR is at get_device_parent+0x50/0x1b8
pc : [<c02f1dd0>] lr : [<c01cb248>] psr: 60000013
sp : ef04bdc8 ip : 00000000 fp : c0446180
r10: ef216e38 r9 : c03af5d0 r8 : ef275c18
r7 : 00000000 r6 : c0476c14 r5 : ef275c18 r4 : ef095840
r3 : ef04a000 r2 : 00000001 r1 : 00000000 r0 : 000000a4
Flags: nZCv IRQs on FIQs on Mode SVC_32 ISA ARM Segment kernel
Control: 10c5787d Table: 0000404a DAC: 00000015
Process swapper/0 (pid: 1, stack limit = 0xef04a238)
Stack: (0xef04bdc8 to 0xef04c000)
[...]
[<c02f1dd0>] (_raw_spin_lock+0x18/0x54) from [<c01cb248>] (get_device_parent+0x50/0x1b8)
[<c01cb248>] (get_device_parent+0x50/0x1b8) from [<c01cb8d8>] (device_add+0xa4/0x574)
[<c01cb8d8>] (device_add+0xa4/0x574) from [<c020b91c>] (thermal_zone_device_register+0x118/0x938)
[<c020b91c>] (thermal_zone_device_register+0x118/0x938) from [<c0202030>] (power_supply_register+0x170/0x1f8)
[<c0202030>] (power_supply_register+0x170/0x1f8) from [<c02055ec>] (ab8500_btemp_probe+0x208/0x47c)
[<c02055ec>] (ab8500_btemp_probe+0x208/0x47c) from [<c01cf0dc>] (platform_drv_probe+0x14/0x18)
[<c01cf0dc>] (platform_drv_probe+0x14/0x18) from [<c01cde70>] (driver_probe_device+0x74/0x20c)
[<c01cde70>] (driver_probe_device+0x74/0x20c) from [<c01ce094>] (__driver_attach+0x8c/0x90)
[<c01ce094>] (__driver_attach+0x8c/0x90) from [<c01cc640>] (bus_for_each_dev+0x4c/0x80)
[<c01cc640>] (bus_for_each_dev+0x4c/0x80) from [<c01cd6b4>] (bus_add_driver+0x16c/0x23c)
[<c01cd6b4>] (bus_add_driver+0x16c/0x23c) from [<c01ce54c>] (driver_register+0x78/0x14c)
[<c01ce54c>] (driver_register+0x78/0x14c) from [<c00086ac>] (do_one_initcall+0xfc/0x164)
[<c00086ac>] (do_one_initcall+0xfc/0x164) from [<c02e89c8>] (kernel_init+0x120/0x2b8)
[<c02e89c8>] (kernel_init+0x120/0x2b8) from [<c000e358>] (ret_from_fork+0x14/0x3c)
Code: e3c3303f e5932004 e2822001 e5832004 (e1903f9f)
---[ end trace ed9df72941b5bada ]---
Signed-off-by: Rajanikanth H.V <rajanikanth.hv@stericsson.com>
Cc: stable@vger.kernel.org
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
This patch affects on Android battery indicator. Battery driver should
send uevent message when battery status changes in order to get Android
battery level dynamically updated. Delayed work was added to periodically
check battery status and capacity.
Signed-off-by: Evgeny Romanov <romanov@neurosoft.ru>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
If charging is started before USB enumeration of an Accessory
Charger Adapter has finished, the AB8500 will generate a
VBUS_ERROR. This in turn results in timeouts and delays the
enumeration with around 15 seconds. This patch delays the
charging and then ramps currents slowly to avoid VBUS errors.
The delay allows the enumeration to have finished before
charging is turned on.
Signed-off-by: Martin Sjoblom <martin.w.sjoblom@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Tested-by: Jonas ABERG <jonas.aberg@stericsson.com>
None of the aforementioned components have their own dedicated
platform data structures anymore. Instead they have all been
merged into one big Battery Management container. Let's remove
them and place all the nice newly added attributes into the core
container.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
When the charging safety timer elapses, the battery health is
shown as "Good". This is misleading and also makes it difficult
to distinguish issues relating to discharging despite the fact
that the charger is still connected.
When in actual fact a safety timer elapse is an indication of a
fault in the battery. Here we make this clearer by reporting
POWER_SUPPLY_HEALTH_UNSPEC_FAILURE instead.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
GPLv2+ is not a valid license string. Replace it with one that is.
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
As HZ is a full-second, there is little point in rounding it.
Let's save a few cycles by using HZ directly.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
The Linux Power Supply framework expects battery temperatures to have
a resolution of 0.1 degree Celsius; however, the AB8500 btemp driver
supplies a battery temperature resolution of 1 degree Celsius. We
therefore have to use a factor 10 on the measured values.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Today the battery recharge is determined with a voltage threshold. This
voltage threshold is only valid when the battery is relaxed. In charging
algorithm the voltage read is the loaded battery voltage and no
compensation is done to get the relaxed voltage. When maintenance
charging is not selected, this makes the recharging condition to almost
immediately activate when there is a discharge present on the battery.
Depending on which vendor the battery comes from this behavior can wear
out the battery much faster than normal.
The fuelgauge driver is responsible to monitor the actual battery
capacity and is able to estimate the remaining capacity. It is better to
use the remaining capacity as a limit to determine when battery should
be recharged.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Marcus Cooper <marcus.xm.cooper@stericsson.com>
Reviewed-by: Hakan BERG <hakan.berg@stericsson.com>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Doing so provides a greater degree of accuracy when dealing with
time-frames between 1us and 20ms. msleep() is only accurate for
wake-ups greater than 20ms.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Jonas ABERG <jonas.aberg@stericsson.com>
Reviewed-by: Johan BJORNSTEDT <johan.bjornstedt@stericsson.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Add two new work queues to provide USB and AC charger disconnect
detection.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>