USB: cdc_acm: Fix oops when Droids MuIn LCD is connected
The Droids MuIn LCD operates like a serial remote terminal. Data received are displayed directly on the LCD. This patch fixes the kernel null pointer oops when it is plugged in. Add NO_DATA_INTERFACE quirk to tell the driver that "control" and "data" interfaces are not separated for this device, which prevents dereferencing a null pointer in the device probe code. Signed-off-by: Erik Slagter <erik@slagter.name> Signed-off-by: Maxin B. John <maxin.john@gmail.com> Tested-by: Erik Slagter <erik@slagter.name> Cc: stable <stable@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:

committed by
Greg Kroah-Hartman

parent
a9df304cf7
commit
fd5054c169
@@ -126,3 +126,4 @@ struct acm {
|
||||
#define SINGLE_RX_URB 2
|
||||
#define NO_CAP_LINE 4
|
||||
#define NOT_A_MODEM 8
|
||||
#define NO_DATA_INTERFACE 16
|
||||
|