hwmon: (lm85) Add support for ADT7468 high-frequency PWM mode

The ADT7468 supports a high-frequency PWM output mode where all PWM
outputs are driven by a 22.5 kHz clock. Add support for this mode, and
document it, as it may surprise the user that setting one PWM output
frequency also affects the other PWM outputs.

Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Darrick J. Wong <djwong@us.ibm.com>
Acked-by: Guenter Roeck <guenter.roeck@ericsson.com>
This commit is contained in:
Jean Delvare
2010-10-28 20:31:50 +02:00
committato da Jean Delvare
parent c36364dbf3
commit f6c61cff8b
2 ha cambiato i file con 35 aggiunte e 7 eliminazioni

Vedi File

@@ -101,6 +101,13 @@ Devices has confirmed this "bug". The ADT7463 is reported to work as
described in the documentation. The current lm85 driver does not show the
offset register.
The ADT7468 has a high-frequency PWM mode, where all PWM outputs are
driven by a 22.5 kHz clock. This is a global mode, not per-PWM output,
which means that setting any PWM frequency above 11.3 kHz will switch
all 3 PWM outputs to a 22.5 kHz frequency. Conversely, setting any PWM
frequency below 11.3 kHz will switch all 3 PWM outputs to a frequency
between 10 and 100 Hz, which can then be tuned separately.
See the vendor datasheets for more information. There is application note
from National (AN-1260) with some additional information about the LM85.
The Analog Devices datasheet is very detailed and describes a procedure for