ARM: mx31: Replace clk_register_clkdev with clock DT lookup
Similarly as it was done for mx6q, use a DT lookup in order to make maintainance task for the clock devices easier. Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com> Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
This commit is contained in:

committed by
Sascha Hauer

parent
8a1a954038
commit
ef0e4a606f
@@ -45,6 +45,8 @@
|
||||
compatible = "fsl,imx31-uart", "fsl,imx21-uart";
|
||||
reg = <0x43f90000 0x4000>;
|
||||
interrupts = <45>;
|
||||
clocks = <&clks 10>, <&clks 30>;
|
||||
clock-names = "ipg", "per";
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
@@ -52,12 +54,16 @@
|
||||
compatible = "fsl,imx31-uart", "fsl,imx21-uart";
|
||||
reg = <0x43f94000 0x4000>;
|
||||
interrupts = <32>;
|
||||
clocks = <&clks 10>, <&clks 31>;
|
||||
clock-names = "ipg", "per";
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
uart4: serial@43fb0000 {
|
||||
compatible = "fsl,imx31-uart", "fsl,imx21-uart";
|
||||
reg = <0x43fb0000 0x4000>;
|
||||
clocks = <&clks 10>, <&clks 49>;
|
||||
clock-names = "ipg", "per";
|
||||
interrupts = <46>;
|
||||
status = "disabled";
|
||||
};
|
||||
@@ -66,6 +72,8 @@
|
||||
compatible = "fsl,imx31-uart", "fsl,imx21-uart";
|
||||
reg = <0x43fb4000 0x4000>;
|
||||
interrupts = <47>;
|
||||
clocks = <&clks 10>, <&clks 50>;
|
||||
clock-names = "ipg", "per";
|
||||
status = "disabled";
|
||||
};
|
||||
};
|
||||
@@ -81,8 +89,17 @@
|
||||
compatible = "fsl,imx31-uart", "fsl,imx21-uart";
|
||||
reg = <0x5000c000 0x4000>;
|
||||
interrupts = <18>;
|
||||
clocks = <&clks 10>, <&clks 48>;
|
||||
clock-names = "ipg", "per";
|
||||
status = "disabled";
|
||||
};
|
||||
|
||||
clks: ccm@53f80000{
|
||||
compatible = "fsl,imx31-ccm";
|
||||
reg = <0x53f80000 0x4000>;
|
||||
interrupts = <0 31 0x04 0 53 0x04>;
|
||||
#clock-cells = <1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|