iio: ad_sigma_delta: Properly handle SPI bus locking vs CS assertion

For devices from the SigmaDelta family we need to keep CS low when doing a
conversion, since the device will use the MISO line as a interrupt to
indicate that the conversion is complete.

This is why the driver locks the SPI bus and when the SPI bus is locked
keeps as long as a conversion is going on. The current implementation gets
one small detail wrong though. CS is only de-asserted after the SPI bus is
unlocked. This means it is possible for a different SPI device on the same
bus to send a message which would be wrongfully be addressed to the
SigmaDelta device as well. Make sure that the last SPI transfer that is
done while holding the SPI bus lock de-asserts the CS signal.

Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Alexandru Ardelean <Alexandru.Ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Lars-Peter Clausen
2019-03-19 13:37:55 +02:00
committed by Jonathan Cameron
parent 6ec417d2f1
commit df1d80aee9
2 changed files with 12 additions and 5 deletions

View File

@@ -69,6 +69,7 @@ struct ad_sigma_delta {
bool irq_dis;
bool bus_locked;
bool keep_cs_asserted;
uint8_t comm;