ath9k: add calibration timeout for AR9002

ADC & I/Q calibrations could take infinite time to comple, since they
depend on received frames. In particular the I/Q mismatch calibration
requires receiving of OFDM frames for completion. But in the 2.4GHz
band, a station could receive only CCK frames for a very long time.

And while we wait for the completion of one of the mentioned
calibrations, the NF calibration is blocked. Moreover, in some
environments, I/Q calibration is unable to complete until a correct
noise calibration will be performed due to AGC behaviour.

In order to avoid delaying NF calibration on forever, limit the maximum
duration of ADCs & I/Q calibrations. If the calibration is not completed
within the maximum time, it will be interrupted and a next calibration
will be performed. The code that selects the next calibration has been
reworked to the loop so incompleted calibration will be respinned later.

А maximum calibration time of 30 seconds was selected to give the
calibration enough time to complete and to not interfere with the long
(NF) calibration.

Run tested with AR9220.

Signed-off-by: Sergey Ryazanov <ryazanov.s.a@gmail.com>
Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
Link: https://lore.kernel.org/r/20200424004923.17129-7-ryazanov.s.a@gmail.com
这个提交包含在:
Sergey Ryazanov
2020-04-24 03:49:23 +03:00
提交者 Kalle Valo
父节点 ded6ff15a1
当前提交 d8d20845c7
修改 3 个文件,包含 25 行新增2 行删除

查看文件

@@ -834,6 +834,7 @@ struct ath_hw {
/* Calibration */
u32 supp_cals;
unsigned long cal_start_time;
struct ath9k_cal_list iq_caldata;
struct ath9k_cal_list adcgain_caldata;
struct ath9k_cal_list adcdc_caldata;