um: pass siginfo to guest process
UML guest processes now get correct siginfo_t for SIGTRAP, SIGFPE, SIGILL and SIGBUS. Specifically, si_addr and si_code are now correct where previously they were si_addr = NULL and si_code = 128. Signed-off-by: Martin Pärtel <martin.partel@gmail.com> Signed-off-by: Richard Weinberger <richard@nod.at>
This commit is contained in:

committed by
Richard Weinberger

parent
d4afcba95f
commit
d3c1cfcdb4
@@ -20,7 +20,8 @@ struct irq_fd {
|
||||
|
||||
enum { IRQ_READ, IRQ_WRITE };
|
||||
|
||||
extern void sigio_handler(int sig, struct uml_pt_regs *regs);
|
||||
struct siginfo;
|
||||
extern void sigio_handler(int sig, struct siginfo *unused_si, struct uml_pt_regs *regs);
|
||||
extern void free_irq_by_fd(int fd);
|
||||
extern void reactivate_fd(int fd, int irqnum);
|
||||
extern void deactivate_fd(int fd, int irqnum);
|
||||
|