Merge tag 'staging-4.11-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/staging

Pull staging/iio driver updates from Greg KH:
 "Here is the big staging and iio driver patchsets for 4.11-rc1.

  We almost broke even this time around, with only a few thousand lines
  added overall, as we removed the old and obsolete i4l code, but added
  some new drivers for the RPi platform, as well as adding some new IIO
  drivers.

  All of these have been in linux-next for a while with no reported
  issues"

* tag 'staging-4.11-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/staging: (669 commits)
  Staging: vc04_services: Fix the "space prohibited" code style errors
  Staging: vc04_services: Fix the "wrong indent" code style errors
  staging: octeon: Use net_device_stats from struct net_device
  Staging: rtl8192u: ieee80211: ieee80211.h - style fix
  Staging: rtl8192u: ieee80211: ieee80211_tx.c - style fix
  Staging: rtl8192u: ieee80211: rtl819x_BAProc.c - style fix
  Staging: rtl8192u: ieee80211: ieee80211_module.c - style fix
  Staging: rtl8192u: ieee80211: rtl819x_TSProc.c - style fix
  Staging: rtl8192u: r8192U.h - style fix
  Staging: rtl8192u: r8192U_core.c - style fix
  Staging: rtl8192u: r819xU_cmdpkt.c - style fix
  staging: rtl8192u: blank lines aren't necessary before a close brace '}'
  staging: rtl8192u: Adding space after enum and struct definition
  staging: rtl8192u: Adding space after struct definition
  Staging: ks7010: Add required and preferred spaces around operators
  Staging: ks7010: ks*: Remove redundant blank lines
  Staging: ks7010: ks*: Add missing blank lines after declarations
  staging: visorbus, replace init_timer with setup_timer
  staging: vt6656: rxtx.c Removed multiple dereferencing
  staging: vt6656: Alignment match open parenthesis
  ...
This commit is contained in:
Linus Torvalds
2017-02-22 12:14:01 -08:00
669 changed files with 25683 additions and 20835 deletions

View File

@@ -170,6 +170,16 @@ Description:
Has all of the equivalent parameters as per voltageY. Units
after application of scale and offset are m/s^2.
What: /sys/bus/iio/devices/iio:deviceX/in_gravity_x_raw
What: /sys/bus/iio/devices/iio:deviceX/in_gravity_y_raw
What: /sys/bus/iio/devices/iio:deviceX/in_gravity_z_raw
KernelVersion: 4.11
Contact: linux-iio@vger.kernel.org
Description:
Gravity in direction x, y or z (may be arbitrarily assigned
but should match other such assignments on device).
Units after application of scale and offset are m/s^2.
What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_x_raw
What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_y_raw
What: /sys/bus/iio/devices/iio:deviceX/in_anglvel_z_raw
@@ -805,7 +815,7 @@ Description:
attribute. E.g. if in_voltage0_raw_thresh_rising_value is set to 1200
and in_voltage0_raw_thresh_rising_hysteresis is set to 50. The event
will get activated once in_voltage0_raw goes above 1200 and will become
deactived again once the value falls below 1150.
deactivated again once the value falls below 1150.
What: /sys/.../events/in_accel_x_raw_roc_rising_value
What: /sys/.../events/in_accel_x_raw_roc_falling_value
@@ -1245,7 +1255,8 @@ Description:
reflectivity of infrared or ultrasound emitted.
Often these sensors are unit less and as such conversion
to SI units is not possible. Higher proximity measurements
indicate closer objects, and vice versa.
indicate closer objects, and vice versa. Units after
application of scale and offset are meters.
What: /sys/.../iio:deviceX/in_illuminance_input
What: /sys/.../iio:deviceX/in_illuminance_raw

View File

@@ -0,0 +1,18 @@
What: /sys/bus/iio/devices/triggerX/trigger_polarity
KernelVersion: 4.11
Contact: fabrice.gasnier@st.com
Description:
The STM32 ADC can be configured to use external trigger sources
(e.g. timers, pwm or exti gpio). Then, it can be tuned to start
conversions on external trigger by either:
- "rising-edge"
- "falling-edge"
- "both-edges".
Reading returns current trigger polarity.
Writing value before enabling conversions sets trigger polarity.
What: /sys/bus/iio/devices/triggerX/trigger_polarity_available
KernelVersion: 4.11
Contact: fabrice.gasnier@st.com
Description:
List all available trigger_polarity settings.

View File

@@ -0,0 +1,22 @@
What /sys/bus/iio/devices/iio:deviceX/sensor_sensitivity
Date: January 2017
KernelVersion: 4.11
Contact: linux-iio@vger.kernel.org
Description:
Show or set the gain boost of the amp, from 0-31 range.
default 31
What /sys/bus/iio/devices/iio:deviceX/sensor_max_range
Date: January 2017
KernelVersion: 4.11
Contact: linux-iio@vger.kernel.org
Description:
Show or set the maximum range between the sensor and the
first object echoed in meters. Default value is 6.020.
This setting limits the time the driver is waiting for a
echo.
Showing the range of available values is represented as the
minimum value, the step and the maximum value, all enclosed
in square brackets.
Example:
[0.043 0.043 11.008]

View File

@@ -0,0 +1,29 @@
What: /sys/bus/iio/devices/triggerX/master_mode_available
KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the list possible master modes which are:
- "reset" : The UG bit from the TIMx_EGR register is used as trigger output (TRGO).
- "enable" : The Counter Enable signal CNT_EN is used as trigger output.
- "update" : The update event is selected as trigger output.
For instance a master timer can then be used as a prescaler for a slave timer.
- "compare_pulse" : The trigger output send a positive pulse when the CC1IF flag is to be set.
- "OC1REF" : OC1REF signal is used as trigger output.
- "OC2REF" : OC2REF signal is used as trigger output.
- "OC3REF" : OC3REF signal is used as trigger output.
- "OC4REF" : OC4REF signal is used as trigger output.
What: /sys/bus/iio/devices/triggerX/master_mode
KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the current master modes.
Writing set the master mode
What: /sys/bus/iio/devices/triggerX/sampling_frequency
KernelVersion: 4.11
Contact: benjamin.gaignard@st.com
Description:
Reading returns the current sampling frequency.
Writing an value different of 0 set and start sampling.
Writing 0 stop sampling.