ARM: dts: at91: Fix ADC trigger nodes

The triggers don't need a reg property, remove it when prenset. Also remove
the unit-address from their name.

This solves:
Warning (unit_address_vs_reg): Node /ahb/apb/adc@fc034000/trigger@0 has a unit name, but no reg property
Warning (unit_address_vs_reg): Node /ahb/apb/adc@fc034000/trigger@1 has a unit name, but no reg property
Warning (unit_address_vs_reg): Node /ahb/apb/adc@fc034000/trigger@2 has a unit name, but no reg property
Warning (unit_address_vs_reg): Node /ahb/apb/adc@fc034000/trigger@3 has a unit name, but no reg property

Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
This commit is contained in:
Alexandre Belloni
2016-07-12 22:16:38 +02:00
父節點 3cf265662c
當前提交 c94afa132b
共有 6 個文件被更改,包括 24 次插入44 次删除

查看文件

@@ -1226,22 +1226,22 @@
atmel,adc-ts-pressure-threshold = <10000>;
status = "disabled";
trigger@0 {
trigger0 {
trigger-name = "external-rising";
trigger-value = <0x1>;
trigger-external;
};
trigger@1 {
trigger1 {
trigger-name = "external-falling";
trigger-value = <0x2>;
trigger-external;
};
trigger@2 {
trigger2 {
trigger-name = "external-any";
trigger-value = <0x3>;
trigger-external;
};
trigger@3 {
trigger3 {
trigger-name = "continuous";
trigger-value = <0x6>;
};