hwmon: (pmbus/lm25066) Add support for LM25063

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
このコミットが含まれているのは:
Guenter Roeck
2013-03-16 10:25:04 -07:00
コミット c8ccab7ab5
2個のファイルの変更101行の追加10行の削除

ファイルの表示

@@ -8,6 +8,11 @@ Supported chips:
Datasheets:
http://www.ti.com/lit/gpn/lm25056
http://www.ti.com/lit/gpn/lm25056a
* TI LM25063
Prefix: 'lm25063'
Addresses scanned: -
Datasheet:
To be announced
* National Semiconductor LM25066
Prefix: 'lm25066'
Addresses scanned: -
@@ -32,7 +37,7 @@ Description
-----------
This driver supports hardware montoring for National Semiconductor / TI LM25056,
LM25066, LM5064, and LM5064 Power Management, Monitoring, Control, and
LM25063, LM25066, LM5064, and LM5066 Power Management, Monitoring, Control, and
Protection ICs.
The driver is a client driver to the core PMBus driver. Please see
@@ -64,8 +69,12 @@ in1_input Measured input voltage.
in1_average Average measured input voltage.
in1_min Minimum input voltage.
in1_max Maximum input voltage.
in1_crit Critical high input voltage (LM25063 only).
in1_lcrit Critical low input voltage (LM25063 only).
in1_min_alarm Input voltage low alarm.
in1_max_alarm Input voltage high alarm.
in1_lcrit_alarm Input voltage critical low alarm (LM25063 only).
in1_crit_alarm Input voltage critical high alarm. (LM25063 only).
in2_label "vmon"
in2_input Measured voltage on VAUX pin
@@ -80,12 +89,16 @@ in3_input Measured output voltage.
in3_average Average measured output voltage.
in3_min Minimum output voltage.
in3_min_alarm Output voltage low alarm.
in3_highest Historical minimum output voltage (LM25063 only).
in3_lowest Historical maximum output voltage (LM25063 only).
curr1_label "iin"
curr1_input Measured input current.
curr1_average Average measured input current.
curr1_max Maximum input current.
curr1_crit Critical input current (LM25063 only).
curr1_max_alarm Input current high alarm.
curr1_crit_alarm Input current critical high alarm (LM25063 only).
power1_label "pin"
power1_input Measured input power.
@@ -95,6 +108,11 @@ power1_alarm Input power alarm
power1_input_highest Historical maximum power.
power1_reset_history Write any value to reset maximum power history.
power2_label "pout". LM25063 only.
power2_input Measured output power.
power2_max Maximum output power limit.
power2_crit Critical output power limit.
temp1_input Measured temperature.
temp1_max Maximum temperature.
temp1_crit Critical high temperature.