e1000e: i219 fix unit hang on reset and runtime D3

Unit hang may occur if multiple descriptors are available in the rings
during reset or runtime suspend. This state can be detected by testing
bit 8 in the FEXTNVM7 register. If this bit is set and there are pending
descriptors in one of the rings, we must flush them prior to reset. Same
applies entering runtime suspend.

Signed-off-by: Yanir Lubetkin <yanirx.lubetkin@intel.com>
Reviewed-by: Alexander Duyck <alexander.h.duyck@redhat.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
This commit is contained in:
Yanir Lubetkin
2015-04-14 02:20:21 +03:00
committed by Jeff Kirsher
parent df905ceae3
commit ad851fbb73
3 changed files with 108 additions and 0 deletions

View File

@@ -38,6 +38,7 @@
#define E1000_FEXTNVM4 0x00024 /* Future Extended NVM 4 - RW */
#define E1000_FEXTNVM6 0x00010 /* Future Extended NVM 6 - RW */
#define E1000_FEXTNVM7 0x000E4 /* Future Extended NVM 7 - RW */
#define E1000_FEXTNVM11 0x5BBC /* Future Extended NVM 11 - RW */
#define E1000_PCIEANACFG 0x00F18 /* PCIE Analog Config */
#define E1000_FCT 0x00030 /* Flow Control Type - RW */
#define E1000_VET 0x00038 /* VLAN Ether Type - RW */