power_supply: Charger-Manager: Add properties for power-supply-class
Charger Manager provides power-supply-class aggregating information from multiple chargers and a fuel-gauge. Signed-off-by: Donggeun Kim <dg77.kim@samsung.com> Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This commit is contained in:

committed by
Anton Vorontsov

parent
3bb3dbbd56
commit
ad3d13eee7
@@ -98,6 +98,11 @@ battery), an instance of Charger Manager is attached to it.
|
||||
|
||||
struct charger_desc {
|
||||
|
||||
char *psy_name;
|
||||
: The power-supply-class name of the battery. Default is
|
||||
"battery" if psy_name is NULL. Users can access the psy entries
|
||||
at "/sys/class/power_supply/[psy_name]/".
|
||||
|
||||
enum polling_modes polling_mode;
|
||||
: CM_POLL_DISABLE: do not poll this battery.
|
||||
CM_POLL_ALWAYS: always poll this battery.
|
||||
@@ -106,6 +111,12 @@ enum polling_modes polling_mode;
|
||||
CM_POLL_CHARGING_ONLY: poll this battery if and only if the
|
||||
battery is being charged.
|
||||
|
||||
unsigned int fullbatt_uV;
|
||||
: If specified with a non-zero value, Charger Manager assumes
|
||||
that the battery is full (capacity = 100) if the battery is not being
|
||||
charged and the battery voltage is equal to or greater than
|
||||
fullbatt_uV.
|
||||
|
||||
unsigned int polling_interval_ms;
|
||||
: Required polling interval in ms. Charger Manager will poll
|
||||
this battery every polling_interval_ms or more frequently.
|
||||
@@ -131,10 +142,13 @@ char *psy_fuel_gauge;
|
||||
: Power-supply-class name of the fuel gauge.
|
||||
|
||||
int (*temperature_out_of_range)(int *mC);
|
||||
bool measure_battery_temp;
|
||||
: This callback returns 0 if the temperature is safe for charging,
|
||||
a positive number if it is too hot to charge, and a negative number
|
||||
if it is too cold to charge. With the variable mC, the callback returns
|
||||
the temperature in 1/1000 of centigrade.
|
||||
The source of temperature can be battery or ambient one according to
|
||||
the value of measure_battery_temp.
|
||||
};
|
||||
|
||||
5. Other Considerations
|
||||
|