mmc: renesas_sdhi: better reset from HS400 mode
[ Upstream commit 0da69dd2155019ed4c444ede0e79ce7a4a6af627 ] Up to now, HS400 adjustment mode was only disabled on soft reset when a calibration table was in use. It is safer, though, to disable it as soon as the instance has an adjustment related quirk set, i.e. bad taps or a calibration table. Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com> Reviewed-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Tested-by: Yoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com> Link: https://lore.kernel.org/r/20221120113457.42010-3-wsa+renesas@sang-engineering.com Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:

committed by
Greg Kroah-Hartman

parent
58e21146c0
commit
a63a1ae134
@@ -537,7 +537,7 @@ static void renesas_sdhi_reset_hs400_mode(struct tmio_mmc_host *host,
|
||||
SH_MOBILE_SDHI_SCC_TMPPORT2_HS400OSEL) &
|
||||
sd_scc_read32(host, priv, SH_MOBILE_SDHI_SCC_TMPPORT2));
|
||||
|
||||
if (priv->adjust_hs400_calib_table)
|
||||
if (priv->quirks && (priv->quirks->hs400_calib_table || priv->quirks->hs400_bad_taps))
|
||||
renesas_sdhi_adjust_hs400_mode_disable(host);
|
||||
|
||||
sd_ctrl_write16(host, CTL_SD_CARD_CLK_CTL, CLK_CTL_SCLKEN |
|
||||
|
Reference in New Issue
Block a user