Pull thermal soc updates from Eduardo Valentin: "Specifics: - mediatek thermal now supports MT8183 - broadcom thermal now supports Stingray - qoirq now supports multiple sensors - fixes on different drivers: rcar, tsens, tegra Some new drivers are still pending further review and I chose to leave them for the next merge window while still sending this material" * 'linus' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal: thermal: rcar_gen3_thermal: Register hwmon sysfs interface thermal/qcom/tsens-common : fix possible object reference leak thermal: tegra: add get_trend ops thermal: tegra: fix memory allocation thermal: tegra: remove unnecessary warnings thermal: mediatek: add support for MT8183 dt-bindings: thermal: add binding document for mt8183 thermal controller thermal: mediatek: add flag for bank selection thermal: mediatek: add thermal controller offset thermal: mediatek: add calibration item thermal: mediatek: add common index of vts settings. thermal: mediatek: fix register index error thermal: qoriq: add multiple sensors support thermal: broadcom: Add Stingray thermal driver dt-bindings: thermal: Add binding document for SR thermal
This commit is contained in:
105
Documentation/devicetree/bindings/thermal/brcm,sr-thermal.txt
Normal file
105
Documentation/devicetree/bindings/thermal/brcm,sr-thermal.txt
Normal file
@@ -0,0 +1,105 @@
|
||||
* Broadcom Stingray Thermal
|
||||
|
||||
This binding describes thermal sensors that is part of Stingray SoCs.
|
||||
|
||||
Required properties:
|
||||
- compatible : Must be "brcm,sr-thermal"
|
||||
- reg : Memory where tmon data will be available.
|
||||
- brcm,tmon-mask: A one cell bit mask of valid TMON sources.
|
||||
Each bit represents single TMON source.
|
||||
- #thermal-sensor-cells : Thermal sensor phandler
|
||||
- polling-delay: Max number of milliseconds to wait between polls.
|
||||
- thermal-sensors: A list of thermal sensor phandles and specifier.
|
||||
specifier value is tmon ID and it should be
|
||||
in correspond with brcm,tmon-mask.
|
||||
- temperature: trip temperature threshold in millicelsius.
|
||||
|
||||
Example:
|
||||
tmons {
|
||||
compatible = "simple-bus";
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
ranges = <0x0 0x0 0x8f100000 0x100>;
|
||||
|
||||
tmon: tmon@0 {
|
||||
compatible = "brcm,sr-thermal";
|
||||
reg = <0x0 0x40>;
|
||||
brcm,tmon-mask = <0x3f>;
|
||||
#thermal-sensor-cells = <1>;
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
ihost0_thermal: ihost0-thermal {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <1000>;
|
||||
thermal-sensors = <&tmon 0>;
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <105000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
ihost1_thermal: ihost1-thermal {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <1000>;
|
||||
thermal-sensors = <&tmon 1>;
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <105000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
ihost2_thermal: ihost2-thermal {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <1000>;
|
||||
thermal-sensors = <&tmon 2>;
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <105000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
ihost3_thermal: ihost3-thermal {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <1000>;
|
||||
thermal-sensors = <&tmon 3>;
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <105000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
crmu_thermal: crmu-thermal {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <1000>;
|
||||
thermal-sensors = <&tmon 4>;
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <105000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
nitro_thermal: nitro-thermal {
|
||||
polling-delay-passive = <0>;
|
||||
polling-delay = <1000>;
|
||||
thermal-sensors = <&tmon 5>;
|
||||
trips {
|
||||
cpu-crit {
|
||||
temperature = <105000>;
|
||||
hysteresis = <0>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
@@ -13,6 +13,7 @@ Required properties:
|
||||
- "mediatek,mt2701-thermal" : For MT2701 family of SoCs
|
||||
- "mediatek,mt2712-thermal" : For MT2712 family of SoCs
|
||||
- "mediatek,mt7622-thermal" : For MT7622 SoC
|
||||
- "mediatek,mt8183-thermal" : For MT8183 family of SoCs
|
||||
- reg: Address range of the thermal controller
|
||||
- interrupts: IRQ for the thermal controller
|
||||
- clocks, clock-names: Clocks needed for the thermal controller. required
|
||||
|