Thermal: set upper and lower limits
set upper and lower limits when binding a thermal cooling device to a thermal zone device. Signed-off-by: Zhang Rui <rui.zhang@intel.com> Reviewed-by: Rafael J. Wysocki <rjw@sisk.pl> Reviewed-by: Eduardo Valentin <eduardo.valentin@ti.com>
This commit is contained in:
@@ -84,7 +84,8 @@ temperature) and throttle appropriate devices.
|
||||
|
||||
1.3 interface for binding a thermal zone device with a thermal cooling device
|
||||
1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
|
||||
int trip, struct thermal_cooling_device *cdev);
|
||||
int trip, struct thermal_cooling_device *cdev,
|
||||
unsigned long upper, unsigned long lower);
|
||||
|
||||
This interface function bind a thermal cooling device to the certain trip
|
||||
point of a thermal zone device.
|
||||
@@ -93,6 +94,12 @@ temperature) and throttle appropriate devices.
|
||||
cdev: thermal cooling device
|
||||
trip: indicates which trip point the cooling devices is associated with
|
||||
in this thermal zone.
|
||||
upper:the Maximum cooling state for this trip point.
|
||||
THERMAL_NO_LIMIT means no upper limit,
|
||||
and the cooling device can be in max_state.
|
||||
lower:the Minimum cooling state can be used for this trip point.
|
||||
THERMAL_NO_LIMIT means no lower limit,
|
||||
and the cooling device can be in cooling state 0.
|
||||
|
||||
1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
|
||||
int trip, struct thermal_cooling_device *cdev);
|
||||
|