ASoC: wm8962: Restore device state after reset in runtime resume

After the device has been reset we need to repeat the same
initialisation we do on probe to make sure that the device is in
a known state.

Tested-by: Nicolin Chen <b42378@freescale.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
Mark Brown
2013-06-07 16:19:58 +01:00
committed by Mark Brown
parent d74e9e7090
commit 9c24b16722

View File

@@ -3756,6 +3756,21 @@ static int wm8962_runtime_resume(struct device *dev)
wm8962_reset(wm8962);
/* SYSCLK defaults to on; make sure it is off so we can safely
* write to registers if the device is declocked.
*/
regmap_update_bits(wm8962->regmap, WM8962_CLOCKING2,
WM8962_SYSCLK_ENA, 0);
/* Ensure we have soft control over all registers */
regmap_update_bits(wm8962->regmap, WM8962_CLOCKING2,
WM8962_CLKREG_OVD, WM8962_CLKREG_OVD);
/* Ensure that the oscillator and PLLs are disabled */
regmap_update_bits(wm8962->regmap, WM8962_PLL2,
WM8962_OSC_ENA | WM8962_PLL2_ENA | WM8962_PLL3_ENA,
0);
regcache_sync(wm8962->regmap);
return 0;