hwmon: (adm1275) Add support for ADM1075
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:

zatwierdzone przez
Guenter Roeck

rodzic
590defe59e
commit
9271126966
@@ -2,6 +2,10 @@ Kernel driver adm1275
|
||||
=====================
|
||||
|
||||
Supported chips:
|
||||
* Analog Devices ADM1075
|
||||
Prefix: 'adm1075'
|
||||
Addresses scanned: -
|
||||
Datasheet: www.analog.com/static/imported-files/data_sheets/ADM1075.pdf
|
||||
* Analog Devices ADM1275
|
||||
Prefix: 'adm1275'
|
||||
Addresses scanned: -
|
||||
@@ -17,13 +21,13 @@ Author: Guenter Roeck <guenter.roeck@ericsson.com>
|
||||
Description
|
||||
-----------
|
||||
|
||||
This driver supports hardware montoring for Analog Devices ADM1275 and ADM1276
|
||||
Hot-Swap Controller and Digital Power Monitor.
|
||||
This driver supports hardware montoring for Analog Devices ADM1075, ADM1275,
|
||||
and ADM1276 Hot-Swap Controller and Digital Power Monitor.
|
||||
|
||||
ADM1275 and ADM1276 are hot-swap controllers that allow a circuit board to be
|
||||
removed from or inserted into a live backplane. They also feature current and
|
||||
voltage readback via an integrated 12-bit analog-to-digital converter (ADC),
|
||||
accessed using a PMBus interface.
|
||||
ADM1075, ADM1275, and ADM1276 are hot-swap controllers that allow a circuit
|
||||
board to be removed from or inserted into a live backplane. They also feature
|
||||
current and voltage readback via an integrated 12-bit analog-to-digital
|
||||
converter (ADC), accessed using a PMBus interface.
|
||||
|
||||
The driver is a client driver to the core PMBus driver. Please see
|
||||
Documentation/hwmon/pmbus for details on PMBus client drivers.
|
||||
@@ -36,6 +40,10 @@ This driver does not auto-detect devices. You will have to instantiate the
|
||||
devices explicitly. Please see Documentation/i2c/instantiating-devices for
|
||||
details.
|
||||
|
||||
The ADM1075, unlike many other PMBus devices, does not support internal voltage
|
||||
or current scaling. Reported voltages, currents, and power are raw measurements,
|
||||
and will typically have to be scaled.
|
||||
|
||||
|
||||
Platform data support
|
||||
---------------------
|
||||
@@ -51,7 +59,8 @@ The following attributes are supported. Limits are read-write, history reset
|
||||
attributes are write-only, all other attributes are read-only.
|
||||
|
||||
in1_label "vin1" or "vout1" depending on chip variant and
|
||||
configuration.
|
||||
configuration. On ADM1075, vout1 reports the voltage on
|
||||
the VAUX pin.
|
||||
in1_input Measured voltage.
|
||||
in1_min Minumum Voltage.
|
||||
in1_max Maximum voltage.
|
||||
@@ -74,3 +83,10 @@ curr1_crit Critical maximum current. Depending on the chip
|
||||
curr1_crit_alarm Critical current high alarm.
|
||||
curr1_highest Historical maximum current.
|
||||
curr1_reset_history Write any value to reset history.
|
||||
|
||||
power1_label "pin1"
|
||||
power1_input Input power.
|
||||
power1_reset_history Write any value to reset history.
|
||||
|
||||
Power attributes are supported on ADM1075 and ADM1276
|
||||
only.
|
||||
|
Reference in New Issue
Block a user