mmc: sh_mobile_sdhi: only change the clock on RCar Gen2+

We had a regression on r8a7740 where the SDHI clock was a generic
peripheral clock, so changing its rate was not desired. This should be
fixed in the clock driver. However, it also shows that the new clock
calculation should only be used on tested systems. Add a check for that.

Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Tested-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
Cette révision appartient à :
Wolfram Sang
2016-05-02 22:25:41 +02:00
révisé par Ulf Hansson
Parent 3d376fb2ea
révision 8fc0099864

Voir le fichier

@@ -168,6 +168,10 @@ static unsigned int sh_mobile_sdhi_clk_update(struct tmio_mmc_host *host,
unsigned int freq, diff, best_freq = 0, diff_min = ~0;
int i;
/* tested only on RCar Gen2+ currently; may work for others */
if (!(host->pdata->flags & TMIO_MMC_MIN_RCAR2))
return clk_get_rate(priv->clk);
/*
* We want the bus clock to be as close as possible to, but no
* greater than, new_clock. As we can divide by 1 << i for