arm: omap3: twl: remove usb phy init data
commit dbc98635e0
("phy: remove the old lookup method") removes
struct phy_consumer but twl-common.c still uses the "phy_consumer"
structure resulting in the following compilation warning.
arch/arm/mach-omap2/twl-common.c:94:21: error: array type has
incomplete element type
struct phy_consumer consumers[] = {
Removed using phy_consumer since twl4030 uses the new lookup
method.
Signed-off-by: Heikki Krogerus <heikki.krogerus@linux.intel.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Reported-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: Greg Kroah-Hartman <greg@kroah.com>
This commit is contained in:

committed by
Greg Kroah-Hartman

parent
3ff6744575
commit
81e1dadfb5
@@ -26,7 +26,6 @@
|
||||
#define __TWL_H_
|
||||
|
||||
#include <linux/types.h>
|
||||
#include <linux/phy/phy.h>
|
||||
#include <linux/input/matrix_keypad.h>
|
||||
|
||||
/*
|
||||
@@ -634,7 +633,6 @@ enum twl4030_usb_mode {
|
||||
struct twl4030_usb_data {
|
||||
enum twl4030_usb_mode usb_mode;
|
||||
unsigned long features;
|
||||
struct phy_init_data *init_data;
|
||||
|
||||
int (*phy_init)(struct device *dev);
|
||||
int (*phy_exit)(struct device *dev);
|
||||
|
Reference in New Issue