RDMA/cxgb4: Add module_params to enable DB FC & Coalescing on T5
Both DB Flow-Control and DB Coalescing are disabled by default on T5 Signed-off-by: Vipul Pandya <vipul@chelsio.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Esse commit está contido em:
@@ -45,6 +45,16 @@ MODULE_DESCRIPTION("Chelsio T4/T5 RDMA Driver");
|
||||
MODULE_LICENSE("Dual BSD/GPL");
|
||||
MODULE_VERSION(DRV_VERSION);
|
||||
|
||||
static int allow_db_fc_on_t5;
|
||||
module_param(allow_db_fc_on_t5, int, 0644);
|
||||
MODULE_PARM_DESC(allow_db_fc_on_t5,
|
||||
"Allow DB Flow Control on T5 (default = 0)");
|
||||
|
||||
static int allow_db_coalescing_on_t5;
|
||||
module_param(allow_db_coalescing_on_t5, int, 0644);
|
||||
MODULE_PARM_DESC(allow_db_coalescing_on_t5,
|
||||
"Allow DB Coalescing on T5 (default = 0)");
|
||||
|
||||
struct uld_ctx {
|
||||
struct list_head entry;
|
||||
struct cxgb4_lld_info lldi;
|
||||
@@ -630,8 +640,19 @@ static struct c4iw_dev *c4iw_alloc(const struct cxgb4_lld_info *infop)
|
||||
if (!ocqp_supported(infop))
|
||||
pr_info("%s: On-Chip Queues not supported on this device.\n",
|
||||
pci_name(infop->pdev));
|
||||
if (!is_t4(infop->adapter_type))
|
||||
db_fc_threshold = 100000;
|
||||
|
||||
if (!is_t4(infop->adapter_type)) {
|
||||
if (!allow_db_fc_on_t5) {
|
||||
db_fc_threshold = 100000;
|
||||
pr_info("DB Flow Control Disabled.\n");
|
||||
}
|
||||
|
||||
if (!allow_db_coalescing_on_t5) {
|
||||
db_coalescing_threshold = -1;
|
||||
pr_info("DB Coalescing Disabled.\n");
|
||||
}
|
||||
}
|
||||
|
||||
devp = (struct c4iw_dev *)ib_alloc_device(sizeof(*devp));
|
||||
if (!devp) {
|
||||
printk(KERN_ERR MOD "Cannot allocate ib device\n");
|
||||
|
Referência em uma nova issue