hv_netvsc: Add handler for physical link speed change

On Hyper-V host 2016 and later, VMs gets an event message of the physical
link speed when vSwitch is changed. This patch handles this message, so
the updated link speed can be reported by ethtool.

Signed-off-by: Haiyang Zhang <haiyangz@microsoft.com>
Reviewed-by: K. Y. Srinivasan <kys@microsoft.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Haiyang Zhang
2016-08-04 10:42:15 -07:00
committed by David S. Miller
parent b37879e6ca
commit 7f5d5af0b2
3 changed files with 25 additions and 7 deletions

View File

@@ -472,9 +472,13 @@ static int negotiate_nvsp_ver(struct hv_device *device,
init_packet->msg.v2_msg.send_ndis_config.mtu = ndev->mtu + ETH_HLEN;
init_packet->msg.v2_msg.send_ndis_config.capability.ieee8021q = 1;
if (nvsp_ver >= NVSP_PROTOCOL_VERSION_5)
if (nvsp_ver >= NVSP_PROTOCOL_VERSION_5) {
init_packet->msg.v2_msg.send_ndis_config.capability.sriov = 1;
/* Teaming bit is needed to receive link speed updates */
init_packet->msg.v2_msg.send_ndis_config.capability.teaming = 1;
}
ret = vmbus_sendpacket(device->channel, init_packet,
sizeof(struct nvsp_message),
(unsigned long)init_packet,