[ALSA] oxygen: add 192 kHz SPDIF input support
Change the oxygen_spdif_input_bits_changed() function so that clock changes on the SPDIF input are correctly detected. This means that sample rates greater than 96 kHz are now supported. Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Jaroslav Kysela <perex@perex.cz>
This commit is contained in:

committed by
Jaroslav Kysela

parent
5a256f862c
commit
7f0b89465b
@@ -85,12 +85,16 @@ static struct snd_pcm_hardware oxygen_hardware[PCM_COUNT] = {
|
||||
SNDRV_PCM_INFO_SYNC_START,
|
||||
.formats = SNDRV_PCM_FMTBIT_S16_LE |
|
||||
SNDRV_PCM_FMTBIT_S32_LE,
|
||||
.rates = SNDRV_PCM_RATE_44100 |
|
||||
.rates = SNDRV_PCM_RATE_32000 |
|
||||
SNDRV_PCM_RATE_44100 |
|
||||
SNDRV_PCM_RATE_48000 |
|
||||
SNDRV_PCM_RATE_64000 |
|
||||
SNDRV_PCM_RATE_88200 |
|
||||
SNDRV_PCM_RATE_96000,
|
||||
.rate_min = 44100,
|
||||
.rate_max = 96000,
|
||||
SNDRV_PCM_RATE_96000 |
|
||||
SNDRV_PCM_RATE_176400 |
|
||||
SNDRV_PCM_RATE_192000,
|
||||
.rate_min = 32000,
|
||||
.rate_max = 192000,
|
||||