iio: hid-sensors: Fix power and report state

In the original HID sensor hub firmwares all Named array enums were
to 0-based. But the most recent hub implemented as 1-based,
because of the implementation by one of the major OS vendor.
Using logical minimum for the field as the base of enum. So we add
logical minimum to the selector values before setting those fields.
Some sensor hub FWs already changed logical minimum from 0 to 1
to reflect this and hope every other vendor will follow.
There is no easy way to add a common HID quirk for NAry elements,
even if the standard specifies these field as NAry, the collection
used to describe selectors is still just "logical".

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Srinivas Pandruvada
2013-11-27 22:19:00 +00:00
committed by Jonathan Cameron
parent 9f740ffa81
commit 751d17e23a
3 changed files with 28 additions and 15 deletions

View File

@@ -25,13 +25,4 @@ config HID_SENSOR_IIO_TRIGGER
If this driver is compiled as a module, it will be named
hid-sensor-trigger.
config HID_SENSOR_ENUM_BASE_QUIRKS
bool "ENUM base quirks for HID Sensor IIO drivers"
depends on HID_SENSOR_IIO_COMMON
help
Say yes here to build support for sensor hub FW using
enumeration, which is using 1 as base instead of 0.
Since logical minimum is still set 0 instead of 1,
there is no easy way to differentiate.
endmenu

View File

@@ -33,24 +33,34 @@ static int hid_sensor_data_rdy_trigger_set_state(struct iio_trigger *trig,
{
struct hid_sensor_common *st = iio_trigger_get_drvdata(trig);
int state_val;
int report_val;
if (state) {
if (sensor_hub_device_open(st->hsdev))
return -EIO;
} else
sensor_hub_device_close(st->hsdev);
state_val =
HID_USAGE_SENSOR_PROP_POWER_STATE_D0_FULL_POWER_ENUM;
report_val =
HID_USAGE_SENSOR_PROP_REPORTING_STATE_ALL_EVENTS_ENUM;
} else {
sensor_hub_device_close(st->hsdev);
state_val =
HID_USAGE_SENSOR_PROP_POWER_STATE_D4_POWER_OFF_ENUM;
report_val =
HID_USAGE_SENSOR_PROP_REPORTING_STATE_NO_EVENTS_ENUM;
}
state_val = state ? 1 : 0;
if (IS_ENABLED(CONFIG_HID_SENSOR_ENUM_BASE_QUIRKS))
++state_val;
st->data_ready = state;
state_val += st->power_state.logical_minimum;
report_val += st->report_state.logical_minimum;
sensor_hub_set_feature(st->hsdev, st->power_state.report_id,
st->power_state.index,
(s32)state_val);
sensor_hub_set_feature(st->hsdev, st->report_state.report_id,
st->report_state.index,
(s32)state_val);
(s32)report_val);