[ALSA] mpu-401: do not require an ACK byte for the ENTER_UART command

The original MPU-401 does not send an ACK byte after processing the
ENTER_UART command, so we better do not try to wait for it.
Many clones get this wrong and do send an ACK, but when interpreting it
as MIDI, it is just a harmless Active Sensing message, and it is likely
to be read and discarded by the interrupt handler before the MIDI input
device is triggered.

Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Jaroslav Kysela <perex@suse.cz>
Este cometimento está contido em:
Clemens Ladisch
2007-10-11 14:15:06 +02:00
cometido por Jaroslav Kysela
ascendente 11be265f7f
cometimento 69d8d3eb4d

Ver ficheiro

@@ -271,7 +271,7 @@ static int snd_mpu401_do_reset(struct snd_mpu401 *mpu)
if (snd_mpu401_uart_cmd(mpu, MPU401_RESET, 1))
return -EIO;
if (!(mpu->info_flags & MPU401_INFO_UART_ONLY) &&
snd_mpu401_uart_cmd(mpu, MPU401_ENTER_UART, 1))
snd_mpu401_uart_cmd(mpu, MPU401_ENTER_UART, 0))
return -EIO;