hwmon: (max34440) Add support for MAX34446
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:

committed by
Guenter Roeck

parent
60b873e332
commit
590defe59e
@@ -11,6 +11,11 @@ Supported chips:
|
||||
Prefixes: 'max34441'
|
||||
Addresses scanned: -
|
||||
Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf
|
||||
* Maxim MAX34446
|
||||
PMBus Power-Supply Data Logger
|
||||
Prefixes: 'max34446'
|
||||
Addresses scanned: -
|
||||
Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf
|
||||
|
||||
Author: Guenter Roeck <guenter.roeck@ericsson.com>
|
||||
|
||||
@@ -19,8 +24,8 @@ Description
|
||||
-----------
|
||||
|
||||
This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel
|
||||
Power-Supply Manager and MAX34441 PMBus 5-Channel Power-Supply Manager
|
||||
and Intelligent Fan Controller.
|
||||
Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager
|
||||
and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger.
|
||||
|
||||
The driver is a client driver to the core PMBus driver. Please see
|
||||
Documentation/hwmon/pmbus for details on PMBus client drivers.
|
||||
@@ -33,6 +38,13 @@ This driver does not auto-detect devices. You will have to instantiate the
|
||||
devices explicitly. Please see Documentation/i2c/instantiating-devices for
|
||||
details.
|
||||
|
||||
For MAX34446, the value of the currX_crit attribute determines if current or
|
||||
voltage measurement is enabled for a given channel. Voltage measurement is
|
||||
enabled if currX_crit is set to 0; current measurement is enabled if the
|
||||
attribute is set to a positive value. Power measurement is only enabled if
|
||||
channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
|
||||
configured for current measurement.
|
||||
|
||||
|
||||
Platform data support
|
||||
---------------------
|
||||
@@ -60,16 +72,27 @@ in[1-6]_lowest Historical minimum voltage.
|
||||
in[1-6]_highest Historical maximum voltage.
|
||||
in[1-6]_reset_history Write any value to reset history.
|
||||
|
||||
MAX34446 only supports in[1-4].
|
||||
|
||||
curr[1-6]_label "iout[1-6]".
|
||||
curr[1-6]_input Measured current. From READ_IOUT register.
|
||||
curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
|
||||
curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
|
||||
curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
|
||||
curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
|
||||
curr[1-4]_average Historical average current (MAX34446 only).
|
||||
curr[1-6]_highest Historical maximum current.
|
||||
curr[1-6]_reset_history Write any value to reset history.
|
||||
|
||||
in6 and curr6 attributes only exist for MAX34440.
|
||||
MAX34446 only supports curr[1-4].
|
||||
|
||||
power[1,3]_label "pout[1,3]"
|
||||
power[1,3]_input Measured power.
|
||||
power[1,3]_average Historical average power.
|
||||
power[1,3]_highest Historical maximum power.
|
||||
|
||||
Power attributes only exist for MAX34446.
|
||||
|
||||
temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register.
|
||||
temp1 is the chip's internal temperature. temp2..temp5
|
||||
@@ -80,7 +103,9 @@ temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register.
|
||||
temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register.
|
||||
temp[1-8]_max_alarm Temperature high alarm.
|
||||
temp[1-8]_crit_alarm Temperature critical high alarm.
|
||||
temp[1-8]_average Historical average temperature (MAX34446 only).
|
||||
temp[1-8]_highest Historical maximum temperature.
|
||||
temp[1-8]_reset_history Write any value to reset history.
|
||||
|
||||
temp7 and temp8 attributes only exist for MAX34440.
|
||||
MAX34446 only supports temp[1-3].
|
||||
|
Reference in New Issue
Block a user