[SCSI] Workaround for disks that report bad optimal transfer length

Not all disks fill out the VPD pages correctly. Add a blacklist flag
that allows us ignore the SBC-3 VPD pages for a given device. The
BLIST_SKIP_VPD_PAGES flag triggers our existing skip_vpd_pages
scsi_device parameter to bypass VPD scanning.

Also blacklist the offending Seagate drive model.

Reported-by: Mike Snitzer <snitzer@redhat.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
此提交包含在:
Martin K. Petersen
2013-04-24 21:19:47 -04:00
提交者 James Bottomley
父節點 c3a634bf78
當前提交 56f2a8016e
共有 3 個檔案被更改,包括 5 行新增0 行删除

查看文件

@@ -228,6 +228,7 @@ static struct {
{"SanDisk", "ImageMate CF-SD1", NULL, BLIST_FORCELUN},
{"SEAGATE", "ST34555N", "0930", BLIST_NOTQ}, /* Chokes on tagged INQUIRY */
{"SEAGATE", "ST3390N", "9546", BLIST_NOTQ},
{"SEAGATE", "ST900MM0006", NULL, BLIST_SKIP_VPD_PAGES},
{"SGI", "RAID3", "*", BLIST_SPARSELUN},
{"SGI", "RAID5", "*", BLIST_SPARSELUN},
{"SGI", "TP9100", "*", BLIST_REPORTLUN2},