wcn36xx: Wait longer for SMD commands to complete
On some wcnss firmwares the start command can take up to 300ms to complete. Currently there is a 200ms timeout for SMD command to complete which causes the start to fail. Increase the timeout to 500ms. Also improve debug information regarding SMD command completion time. Signed-off-by: Pontus Fuchs <pontus.fuchs@gmail.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:

committed by
John W. Linville

orang tua
c951da4615
melakukan
546c505bdc
@@ -24,7 +24,7 @@
|
||||
|
||||
#define WCN36XX_HAL_BUF_SIZE 4096
|
||||
|
||||
#define HAL_MSG_TIMEOUT 200
|
||||
#define HAL_MSG_TIMEOUT 500
|
||||
#define WCN36XX_SMSM_WLAN_TX_ENABLE 0x00000400
|
||||
#define WCN36XX_SMSM_WLAN_TX_RINGS_EMPTY 0x00000200
|
||||
/* The PNO version info be contained in the rsp msg */
|
||||
|
Reference in New Issue