s390/time: always use stckf instead of stck if available
The store clock fast instruction saves a couple of instructions compared to the store clock instruction. Always use stckf instead of stck if it is available. Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com> Reviewed-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:

committed by
Martin Schwidefsky

parent
2739b6d124
commit
473e66baad
@@ -82,7 +82,6 @@ extern unsigned int user_mode;
|
||||
#define MACHINE_FLAG_LPAR (1UL << 12)
|
||||
#define MACHINE_FLAG_SPP (1UL << 13)
|
||||
#define MACHINE_FLAG_TOPOLOGY (1UL << 14)
|
||||
#define MACHINE_FLAG_STCKF (1UL << 15)
|
||||
|
||||
#define MACHINE_IS_VM (S390_lowcore.machine_flags & MACHINE_FLAG_VM)
|
||||
#define MACHINE_IS_KVM (S390_lowcore.machine_flags & MACHINE_FLAG_KVM)
|
||||
@@ -101,7 +100,6 @@ extern unsigned int user_mode;
|
||||
#define MACHINE_HAS_PFMF (0)
|
||||
#define MACHINE_HAS_SPP (0)
|
||||
#define MACHINE_HAS_TOPOLOGY (0)
|
||||
#define MACHINE_HAS_STCKF (0)
|
||||
#else /* __s390x__ */
|
||||
#define MACHINE_HAS_IEEE (1)
|
||||
#define MACHINE_HAS_CSP (1)
|
||||
@@ -113,7 +111,6 @@ extern unsigned int user_mode;
|
||||
#define MACHINE_HAS_PFMF (S390_lowcore.machine_flags & MACHINE_FLAG_PFMF)
|
||||
#define MACHINE_HAS_SPP (S390_lowcore.machine_flags & MACHINE_FLAG_SPP)
|
||||
#define MACHINE_HAS_TOPOLOGY (S390_lowcore.machine_flags & MACHINE_FLAG_TOPOLOGY)
|
||||
#define MACHINE_HAS_STCKF (S390_lowcore.machine_flags & MACHINE_FLAG_STCKF)
|
||||
#endif /* __s390x__ */
|
||||
|
||||