charger-manager: Set current limit of regulator for over current protection
This patch support the protection of host device from over current. The Charger-manager set proper current limit of charger(regulator) for charging according to type of charger cable when external connector is attached. Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com> Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This commit is contained in:

committed by
Anton Vorontsov

parent
bee737bccb
commit
45cd4fb28b
@@ -1001,6 +1001,21 @@ static void charger_extcon_work(struct work_struct *work)
|
||||
{
|
||||
struct charger_cable *cable =
|
||||
container_of(work, struct charger_cable, wq);
|
||||
int ret;
|
||||
|
||||
if (cable->attached && cable->min_uA != 0 && cable->max_uA != 0) {
|
||||
ret = regulator_set_current_limit(cable->charger->consumer,
|
||||
cable->min_uA, cable->max_uA);
|
||||
if (ret < 0) {
|
||||
pr_err("Cannot set current limit of %s (%s)\n",
|
||||
cable->charger->regulator_name, cable->name);
|
||||
return;
|
||||
}
|
||||
|
||||
pr_info("Set current limit of %s : %duA ~ %duA\n",
|
||||
cable->charger->regulator_name,
|
||||
cable->min_uA, cable->max_uA);
|
||||
}
|
||||
|
||||
try_charger_enable(cable->cm, cable->attached);
|
||||
}
|
||||
|
Reference in New Issue
Block a user