mfd: axp20x: Add address extension registers for AXP806 regmap
The AXP806 supports either master/standalone or slave mode. Slave mode allows sharing the serial bus, even with multiple AXP806 which all have the same hardware address. This is done with extra "serial interface address extension", or AXP806_BUS_ADDR_EXT, and "register address extension", or AXP806_REG_ADDR_EXT, registers. The former is read-only, with 1 bit customizable at the factory, and 1 bit depending on the state of an external pin. The latter is writable. Only when the these device addressing bits (in the upper 4 bits of the registers) match, will the device respond to operations on its other registers. Add these 2 registers to the regmap so we can access them. Signed-off-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Lee Jones <lee.jones@linaro.org>
This commit is contained in:
@@ -136,6 +136,7 @@ static const struct regmap_range axp806_writeable_ranges[] = {
|
||||
regmap_reg_range(AXP806_PWR_OUT_CTRL1, AXP806_CLDO3_V_CTRL),
|
||||
regmap_reg_range(AXP20X_IRQ1_EN, AXP20X_IRQ2_EN),
|
||||
regmap_reg_range(AXP20X_IRQ1_STATE, AXP20X_IRQ2_STATE),
|
||||
regmap_reg_range(AXP806_REG_ADDR_EXT, AXP806_REG_ADDR_EXT),
|
||||
};
|
||||
|
||||
static const struct regmap_range axp806_volatile_ranges[] = {
|
||||
@@ -306,7 +307,7 @@ static const struct regmap_config axp806_regmap_config = {
|
||||
.val_bits = 8,
|
||||
.wr_table = &axp806_writeable_table,
|
||||
.volatile_table = &axp806_volatile_table,
|
||||
.max_register = AXP806_VREF_TEMP_WARN_L,
|
||||
.max_register = AXP806_REG_ADDR_EXT,
|
||||
.cache_type = REGCACHE_RBTREE,
|
||||
};
|
||||
|
||||
|
Reference in New Issue
Block a user