drm/amdgpu: add pipeline sync while vmid switch in same ctx

Since vmid-mgr supports vmid sharing in one vm, the same ctx could
get different vmids for two emits without vm flush, vm_flush could
be done in another ring.

Signed-off-by: Chunming Zhou <David1.Zhou@amd.com>
Reviewed-by: Alex Deucher <alexander.deucher@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
Chunming Zhou
2016-04-27 18:07:41 +08:00
committed by Alex Deucher
parent fdff8cfa72
commit 2ba272d7bd
3 changed files with 13 additions and 6 deletions

View File

@@ -799,6 +799,7 @@ struct amdgpu_ring {
unsigned cond_exe_offs;
u64 cond_exe_gpu_addr;
volatile u32 *cond_exe_cpu_addr;
int vmid;
};
/*
@@ -936,7 +937,8 @@ int amdgpu_vm_flush(struct amdgpu_ring *ring,
unsigned vm_id, uint64_t pd_addr,
uint32_t gds_base, uint32_t gds_size,
uint32_t gws_base, uint32_t gws_size,
uint32_t oa_base, uint32_t oa_size);
uint32_t oa_base, uint32_t oa_size,
bool vmid_switch);
void amdgpu_vm_reset_id(struct amdgpu_device *adev, unsigned vm_id);
uint64_t amdgpu_vm_map_gart(const dma_addr_t *pages_addr, uint64_t addr);
int amdgpu_vm_update_page_directory(struct amdgpu_device *adev,