scsi: u14-34f: remove from tree

The driver has not seen any maintainer activity or other work that
wasn't tree wide conversion or clenaups in the entire history of
the git tree.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinicke <hare@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
此提交包含在:
Christoph Hellwig
2016-09-19 08:50:50 -07:00
提交者 Martin K. Petersen
父節點 180a186d98
當前提交 24cbf0f799
共有 5 個檔案被更改,包括 0 行新增2030 行删除

查看文件

@@ -1376,55 +1376,6 @@ config SCSI_T128
To compile this driver as a module, choose M here: the
module will be called t128.
config SCSI_U14_34F
tristate "UltraStor 14F/34F support"
depends on ISA && SCSI && ISA_DMA_API
---help---
This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
The source at <file:drivers/scsi/u14-34f.c> contains some
information about this hardware. If the driver doesn't work out of
the box, you may have to change some settings in
<file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
<http://www.tldp.org/docs.html#howto>. Note that there is also
another driver for the same hardware: "UltraStor SCSI support",
below. You should say Y to both only if you want 24F support as
well.
To compile this driver as a module, choose M here: the
module will be called u14-34f.
config SCSI_U14_34F_TAGGED_QUEUE
bool "enable tagged command queueing"
depends on SCSI_U14_34F
help
This is a feature of SCSI-2 which improves performance: the host
adapter can send several SCSI commands to a device's queue even if
previous commands haven't finished yet.
This is equivalent to the "u14-34f=tc:y" boot option.
config SCSI_U14_34F_LINKED_COMMANDS
bool "enable elevator sorting"
depends on SCSI_U14_34F
help
This option enables elevator sorting for all probed SCSI disks and
CD-ROMs. It definitely reduces the average seek distance when doing
random seeks, but this does not necessarily result in a noticeable
performance improvement: your mileage may vary...
This is equivalent to the "u14-34f=lc:y" boot option.
config SCSI_U14_34F_MAX_TAGS
int "maximum number of queued commands"
depends on SCSI_U14_34F
default "8"
help
This specifies how many SCSI commands can be maximally queued for
each probed SCSI device. You should reduce the default value of 8
only if you have disks with buggy or limited tagged command support.
Minimum is 2 and maximum is 14. This value is also the window size
used by the elevator sorting option above. The effective value used
by the driver for each probed SCSI device is reported at boot time.
This is equivalent to the "u14-34f=mq:8" boot option.
config SCSI_NSP32
tristate "Workbit NinjaSCSI-32Bi/UDE support"
depends on PCI && SCSI && !64BIT