openvswitch: avoid resetting flow key while installing new flow.

since commit commit db74a3335e ("openvswitch: use percpu
flow stats") flow alloc resets flow-key. So there is no need
to reset the flow-key again if OVS is using newly allocated
flow-key.

Signed-off-by: Pravin B Shelar <pshelar@ovn.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
pravin shelar
2016-09-19 13:51:00 -07:00
committed by David S. Miller
parent 190aa3e778
commit 2279994d07
4 changed files with 10 additions and 9 deletions

View File

@@ -41,7 +41,8 @@ size_t ovs_tun_key_attr_size(void);
size_t ovs_key_attr_size(void);
void ovs_match_init(struct sw_flow_match *match,
struct sw_flow_key *key, struct sw_flow_mask *mask);
struct sw_flow_key *key, bool reset_key,
struct sw_flow_mask *mask);
int ovs_nla_put_key(const struct sw_flow_key *, const struct sw_flow_key *,
int attr, bool is_mask, struct sk_buff *);