[S390] cio: failing set online/offline processing.
When unit checks trigger sensing the device state is set to W4SENSE until sense completion; then the device state is set back to ONLINE. If a unit check occurs while set online or set offline requests are processed then it might happen that the device's temporary W4SENSE state causes these functions to terminate, leaving the device in an inconsistent state when the state is set back to ONLINE later on so that the device cannot be set online or offline any longer. To solve this, set online/offline and related rollback or error routines are processed only if the device is in a final or DISCONNECTED state. Signed-off-by: Michael Ernst <mernst@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:

committed by
Martin Schwidefsky

parent
be7a2ddce6
commit
217ee6c64a
@@ -905,6 +905,8 @@ ccw_device_w4sense(struct ccw_device *cdev, enum dev_event dev_event)
|
||||
}
|
||||
call_handler:
|
||||
cdev->private->state = DEV_STATE_ONLINE;
|
||||
/* In case sensing interfered with setting the device online */
|
||||
wake_up(&cdev->private->wait_q);
|
||||
/* Call the handler. */
|
||||
if (ccw_device_call_handler(cdev) && cdev->private->flags.doverify)
|
||||
/* Start delayed path verification. */
|
||||
|
Reference in New Issue