spi: efm32: correct namespacing of location property

Olof Johansson pointed out that usually the company name is picked as
namespace prefix to specific properties. So expect "energymicro,location"
but fall back to the previously introduced name "efm32,location".

Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
Uwe Kleine-König
2014-07-11 10:17:57 +02:00
committed by Mark Brown
parent 7171511eae
commit 10ed7e9847
2 changed files with 14 additions and 7 deletions

View File

@@ -294,10 +294,16 @@ static void efm32_spi_probe_dt(struct platform_device *pdev,
u32 location;
int ret;
ret = of_property_read_u32(np, "efm32,location", &location);
ret = of_property_read_u32(np, "energymicro,location", &location);
if (ret)
/* fall back to wrongly namespaced property */
ret = of_property_read_u32(np, "efm32,location", &location);
if (ret)
/* fall back to old and (wrongly) generic property "location" */
ret = of_property_read_u32(np, "location", &location);
if (!ret) {
dev_dbg(&pdev->dev, "using location %u\n", location);
} else {