ab8500-charger: Add backup battery charge voltages on the ab8540
Add 2.7v, 2.9v, 3.0v, 3.2v and 3.3v charging voltages for backup battery. Before that only 2.5v, 2.6v, 2.8v, 3.1v were available. Signed-off-by: Yang QU <yang.qu@stericsson.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Reviewed-by: Maxime COQUELIN <maxime.coquelin@stericsson.com> Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com> Tested-by: Xiao Mei ZHANG <xiaomei.zhang@stericsson.com>
This commit is contained in:
@@ -2836,6 +2836,7 @@ static int ab8500_charger_usb_get_property(struct power_supply *psy,
|
||||
static int ab8500_charger_init_hw_registers(struct ab8500_charger *di)
|
||||
{
|
||||
int ret = 0;
|
||||
u8 bup_vch_range = 0, vbup33_vrtcn = 0;
|
||||
|
||||
/* Setup maximum charger current and voltage for ABB cut2.0 */
|
||||
if (!is_ab8500_1p1_or_earlier(di->parent)) {
|
||||
@@ -2945,15 +2946,29 @@ static int ab8500_charger_init_hw_registers(struct ab8500_charger *di)
|
||||
}
|
||||
|
||||
/* Backup battery voltage and current */
|
||||
if (di->bm->bkup_bat_v > BUP_VCH_SEL_3P1V)
|
||||
bup_vch_range = BUP_VCH_RANGE;
|
||||
if (di->bm->bkup_bat_v == BUP_VCH_SEL_3P3V)
|
||||
vbup33_vrtcn = VBUP33_VRTCN;
|
||||
|
||||
ret = abx500_set_register_interruptible(di->dev,
|
||||
AB8500_RTC,
|
||||
AB8500_RTC_BACKUP_CHG_REG,
|
||||
di->bm->bkup_bat_v |
|
||||
di->bm->bkup_bat_i);
|
||||
(di->bm->bkup_bat_v & 0x3) | di->bm->bkup_bat_i);
|
||||
if (ret) {
|
||||
dev_err(di->dev, "failed to setup backup battery charging\n");
|
||||
goto out;
|
||||
}
|
||||
if (is_ab8540(di->parent)) {
|
||||
ret = abx500_set_register_interruptible(di->dev,
|
||||
AB8500_RTC,
|
||||
AB8500_RTC_CTRL1_REG,
|
||||
bup_vch_range | vbup33_vrtcn);
|
||||
if (ret) {
|
||||
dev_err(di->dev, "failed to setup backup battery charging\n");
|
||||
goto out;
|
||||
}
|
||||
}
|
||||
|
||||
/* Enable backup battery charging */
|
||||
abx500_mask_and_set_register_interruptible(di->dev,
|
||||
|
Reference in New Issue