clocksource: arch_timer: Fix code to use physical timers when requested
This is a bug fix for using physical arch timers when the arch_timer_use_virtual boolean is false. It restores the arch_counter_get_cntpct() function after removal in0d651e4e
"clocksource: arch_timer: use virtual counters" We need this on certain ARMv7 systems which are architected like this: * The firmware doesn't know and doesn't care about hypervisor mode and we don't want to add the complexity of hypervisor there. * The firmware isn't involved in SMP bringup or resume. * The ARCH timer come up with an uninitialized offset between the virtual and physical counters. Each core gets a different random offset. * The device boots in "Secure SVC" mode. * Nothing has touched the reset value of CNTHCTL.PL1PCEN or CNTHCTL.PL1PCTEN (both default to 1 at reset) One example of such as system is RK3288 where it is much simpler to use the physical counter since there's nobody managing the offset and each time a core goes down and comes back up it will get reinitialized to some other random value. Fixes:0d651e4e65
("clocksource: arch_timer: use virtual counters") Cc: stable@vger.kernel.org Signed-off-by: Sonny Rao <sonnyrao@chromium.org> Acked-by: Catalin Marinas <catalin.marinas@arm.com> Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org> Signed-off-by: Olof Johansson <olof@lixom.net>
This commit is contained in:

committed by
Olof Johansson

parent
f114040e3e
commit
0b46b8a718
@@ -462,7 +462,10 @@ static void __init arch_counter_register(unsigned type)
|
||||
|
||||
/* Register the CP15 based counter if we have one */
|
||||
if (type & ARCH_CP15_TIMER) {
|
||||
arch_timer_read_counter = arch_counter_get_cntvct;
|
||||
if (arch_timer_use_virtual)
|
||||
arch_timer_read_counter = arch_counter_get_cntvct;
|
||||
else
|
||||
arch_timer_read_counter = arch_counter_get_cntpct;
|
||||
} else {
|
||||
arch_timer_read_counter = arch_counter_get_cntvct_mem;
|
||||
|
||||
|
Reference in New Issue