pli1209bc.rst 2.2 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475
  1. .. SPDX-License-Identifier: GPL-2.0
  2. Kernel driver pli1209bc
  3. =======================
  4. Supported chips:
  5. * Digital Supervisor PLI1209BC
  6. Prefix: 'pli1209bc'
  7. Addresses scanned: 0x50 - 0x5F
  8. Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf
  9. Authors:
  10. - Marcello Sylvester Bauer <[email protected]>
  11. Description
  12. -----------
  13. The Vicor PLI1209BC is an isolated digital power system supervisor that provides
  14. a communication interface between a host processor and one Bus Converter Module
  15. (BCM). The PLI communicates with a system controller via a PMBus compatible
  16. interface over an isolated UART interface. Through the PLI, the host processor
  17. can configure, set protection limits, and monitor the BCM.
  18. Sysfs entries
  19. -------------
  20. ======================= ========================================================
  21. in1_label "vin2"
  22. in1_input Input voltage.
  23. in1_rated_min Minimum rated input voltage.
  24. in1_rated_max Maximum rated input voltage.
  25. in1_max Maximum input voltage.
  26. in1_max_alarm Input voltage high alarm.
  27. in1_crit Critical input voltage.
  28. in1_crit_alarm Input voltage critical alarm.
  29. in2_label "vout2"
  30. in2_input Output voltage.
  31. in2_rated_min Minimum rated output voltage.
  32. in2_rated_max Maximum rated output voltage.
  33. in2_alarm Output voltage alarm
  34. curr1_label "iin2"
  35. curr1_input Input current.
  36. curr1_max Maximum input current.
  37. curr1_max_alarm Maximum input current high alarm.
  38. curr1_crit Critical input current.
  39. curr1_crit_alarm Input current critical alarm.
  40. curr2_label "iout2"
  41. curr2_input Output current.
  42. curr2_crit Critical output current.
  43. curr2_crit_alarm Output current critical alarm.
  44. curr2_max Maximum output current.
  45. curr2_max_alarm Output current high alarm.
  46. power1_label "pin2"
  47. power1_input Input power.
  48. power1_alarm Input power alarm.
  49. power2_label "pout2"
  50. power2_input Output power.
  51. power2_rated_max Maximum rated output power.
  52. temp1_input Die temperature.
  53. temp1_alarm Die temperature alarm.
  54. temp1_max Maximum die temperature.
  55. temp1_max_alarm Die temperature high alarm.
  56. temp1_crit Critical die temperature.
  57. temp1_crit_alarm Die temperature critical alarm.
  58. ======================= ========================================================