1234567891011121314151617181920212223242526272829303132333435363738 |
- What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_factory
- Date: August 2021
- KernelVersion: 5.16
- Contact: Jacopo Mondi <[email protected]>
- Description:
- Writing '1' triggers a 'Factory' calibration cycle.
- What: /sys/bus/iio/devices/iio:deviceX/in_concentration_co2_calibration_background
- Date: August 2021
- KernelVersion: 5.16
- Contact: Jacopo Mondi <[email protected]>
- Description:
- Writing '1' triggers a 'Background' calibration cycle.
- What: /sys/bus/iio/devices/iio:deviceX/error_status_available
- Date: August 2021
- KernelVersion: 5.16
- Contact: Jacopo Mondi <[email protected]>
- Description:
- Reading returns the list of possible chip error status.
- Available options are:
- - 'error_fatal': Analog front-end initialization error
- - 'error_i2c': Read/write to non-existing register
- - 'error_algorithm': Corrupted parameters
- - 'error_calibration': Calibration has failed
- - 'error_self_diagnostic': Internal interface failure
- - 'error_out_of_range': Measured concentration out of scale
- - 'error_memory': Error during memory operations
- - 'error_no_measurement': Cleared at first measurement
- - 'error_low_voltage': Sensor regulated voltage too low
- - 'error_measurement_timeout': Unable to complete measurement
- What: /sys/bus/iio/devices/iio:deviceX/error_status
- Date: August 2021
- KernelVersion: 5.16
- Contact: Jacopo Mondi <[email protected]>
- Description:
- Reading returns the current chip error status.
|