Jyoti Kumari 4afef82b70 qcacmn: Handle TWT renegotiation failure case
Generally below process should happen in renegotiation failure
case.
1. TWT setup (successful)
2. TWT setup (renegotiation failure)
3. TWT teardown
4. TWT GET STATUS - 0(dialog ID) 0 0 0
5. TWT setup - successful

Since all WMI TWT events gets executed in WMI thread. So when
renegotiation failure case hits, driver sends TWT
teardown to firmware and waits for twt ack in worker thread.
In same worker thread TWT event needs to be processed.
TWT ack event will not process as it's waiting in same worker
thread and it will get timedout.

As part of fix, break the context in renegotiation and
send the teardown in the new worker context.

Change-Id: Id12cb906b780d3013562c1772e276639a056c8f7
CRs-Fixed: 3207537
2022-06-10 18:58:29 -07:00
..